MycoShare Review version

Experiments /

Pure mycelium (removed from wheat grain composite) · T. versicolor

✓ Reviewed content

Trametes versicolor (commercial (New Generation Mushroom Supplies)) · RMIT University, Melbourne (AU) et al.

Recipe

How this sample was made, step by step
  1. 1

    Substrate

    Not reported

  2. 2

    Sterilisation

    Method
    Autoclaving
    Details
    121 °C, 103.4 kPa, 90 min
  3. 3

    Inoculation

    Fungus
    Trametes versicolor · commercial (New Generation Mushroom Supplies)
    Inoculum
    Grain spawn
    Rate
    25 wt%
  4. 4

    Growth in mould

    Mould
    sterile plastic moulds 100 × 100 mm
  5. 5

    Inactivation

    Method
    Oven drying
    Temperature
    50 °C
    Duration
    48 h
  6. 6

    Specimen & testing

    Geometry
    approx. 10 mg (TGA) or approx. 20 mg (PCFC)
    Measurements
    7

Steps marked “not reported” were not stated in the source. Suggest missing details

Mycelium mass, cleaned of grain residues under the microscope; for TGA and PCFC.

Measurements

Thermal

PropertyValuenTest standardConditions
Onset of thermal decomposition (TGA) 225 °C from PCFC curve
“approx. 225 °C” in the text; main mass loss (approx. 70 %) between 200 and 375 °C
edit

Fire behaviour

PropertyValuenTest standardConditions
PCFC: peak specific heat release rate 67 ± 2 W/g 2 ASTM D7309 1 °C/s to approx. 900 °C in N₂, combustion at 900 °C edit
PCFC: specific total heat release 6.8 ± 0.1 kJ/g 2 ASTM D7309 edit
PCFC: heat release capacity (HRC) 70 ± 1 J/(g·K) 2 ASTM D7309
mean given in the text as 69.5 J/(g·K)
edit
PCFC: temperature at peak heat release 300 ± 1 °C 2 ASTM D7309 edit
Char yield 23 ± 1 wt% 2 ASTM D7309 (PCFC) edit
Char yield 23 ± 0.6 wt% TGA, N₂, 30 °C/min, residue at 600 °C edit

Production

Substrate mix

Not specified.

Fungus & inoculation

Fungus
Trametes versicolor (commercial (New Generation Mushroom Supplies))
Inoculum type
Grain spawn
Inoculation rate [wt%]
25
Sterilisation
Autoclaving
Sterilisation – details
121 °C, 103.4 kPa, 90 min

Growth

Mould / mould material
sterile plastic moulds 100 × 100 mm

Post-processing

Inactivation
Oven drying
Inactivation – temperature [°C]
50
Inactivation – duration [h]
48

Specimen

Specimen geometry
approx. 10 mg (TGA) or approx. 20 mg (PCFC)

Notes

No growth-time effect: TGA of mycelium after 6, 12 and 18 days showed no visible differences. PCFC comparison: PMMA 446 W/g, PLA 375 W/g.

Community feedback

Is something wrong or confirmed by your own tests? Mark the experiment as ✓ correct or ✗ not correct and explain why.

No comments yet.

Add your assessment

What is right or wrong about this experiment? Please give a reason or a source.

Your agreement is recorded with date and time. Your name is shown with the comment. See the privacy policy.

Comments appear immediately; the editorial team may remove inappropriate ones.